Short answer: an offset pivot door gives nearly the whole opening. You lose the strip behind the axis, half the leaf thickness, the stop on the lock jamb and, under some rules, the pull that ends up in the opening. Width is easy to meet if the opening is sized for it. On a heavy pivot leaf the harder parts are opening force, closing speed and a level threshold, and most of these rules do not cover a private villa.
How is clear opening measured on an offset pivot door?
With the leaf open at 90°, from the stop on the lock jamb to the face of the leaf. The 2010 ADA Standards measure “between the face of the door and the stop, with the door open 90 degrees”. An open offset leaf stands just inside the pivot jamb, so four things come off the opening:
- Axis distance: the pivot point (leaf edge to axis) plus the side gap (offset or centre-hung).
- Half the leaf thickness, because the axis runs through the middle of the leaf.
- The lock-side stop: the rebate or stop profile the leaf closes against.
- Whatever is on the leaf face that turns into the opening: pull, reader, escutcheon. On an inward-opening door, that is the outside face.
The rules treat point 4 differently:
- ADA (404.2.3): measured to the leaf face. Hardware may project up to 100 mm between 865 and 2,030 mm above the floor, but “There shall be no projections into the required clear opening width lower than 34 inches (865 mm)”.
- Approved Document M Volume 2 (England, buildings other than dwellings): effective clear width runs from the stop “to any obstruction on the hinge side”, including “projecting door opening furniture”.
- Approved Document M Volume 1 (dwellings): handles and other door furniture may be ignored.
- BS 8300-2:2018, as the Guild of Architectural Ironmongers (GAI) summarises it: projecting door furniture counts as an obstruction.
If a wall or furniture stops the leaf short of 90°, the passage is narrower than the figure on the drawing.
How wide is a 1,100 mm pivot opening? A worked example
This is our example, with assumed figures: a 1,100 mm opening inside the frame, an 80 mm leaf, a 70 mm pivot point, the 13 mm side gap worked out in our offset guide, a 20 mm stop on the lock jamb, and an outside pull projecting 75 mm on an inward-opening leaf. Our arithmetic:
| Step | Calculation | Result |
|---|---|---|
| Axis from the pivot jamb | 70 + 13 | 83 mm |
| Face of the open leaf from the pivot jamb | 83 + 80 ÷ 2 | 123 mm |
| Clear width to the leaf face | 1,100 − 123 − 20 | 957 mm |
| Clear width to the pull | 957 − 75 | 882 mm |
This opening loses 143 mm before the pull and 218 mm with it. To size an opening, work backwards: the required width plus 143 mm, plus 75 mm where the rule counts the pull. Wider openings, and a comparison with sliding doors, are in pivot or sliding entrance doors.
Does that example meet the main accessibility rules?
On width, yes, except where a new public building in England needs 1,000 mm measured to the pull. Our arithmetic, for the same leaf, stop and pull:
| Rule | Minimum clear width | Measured to | 1,100 mm example | Opening needed |
|---|---|---|---|---|
| US, 2010 ADA Standards, 404.2.3 | 815 mm; 915 mm if the opening is more than 610 mm deep | Leaf face; hardware up to 100 mm, 865–2,030 mm high | 957 mm: meets | 958 mm (1,058 mm if deep) |
| England, ADM Vol 2, external door to a new building used by the public | 1,000 mm (775 mm existing) | Any obstruction, pull included | 882 mm: 118 mm short | 1,218 mm |
| England, ADM Vol 1, M4(2) and M4(3) entrance | 850 mm | Leaf face; handles ignored | 957 mm: meets | 993 mm |
| England, ADM Vol 1, M4(1) entrance | 775 mm | Leaf face; handles ignored | 957 mm: meets | 918 mm |
| Australia, AS 1428.1 | 850 mm | Clear of obstructions; ask how hardware counts | 882–957 mm: meets | 993–1,068 mm |
| Australia, Livable Housing Design Standard, entrance door | 820 mm | Clear of leaf and frames | 957 mm: meets | 963 mm |
Under the ADA, a long vertical pull that runs below 865 mm must leave the required 815 mm free; here 882 mm remains. On a pair, one active leaf must give the width (single, double or unequal).
Which rules apply to a private villa, and which to public buildings?
Most entrance rules are written for public and commercial buildings, not private houses. A house that is partly a business, or a block of flats, can still be covered, so ask the building authority before the opening is fixed. Where no rule applies, 850 mm clear is a sensible target.
- US: the ADA “does not cover strictly residential private apartments and homes” (ADA National Network). Where a home contains a place of public accommodation, coverage “extends to those elements used to enter” it, the door included (28 CFR 36.207). In new construction, at least 60% of public entrances must be accessible. The Fair Housing Act design rules cover buildings of four or more units first occupied after 13 March 1991, with a 32 in minimum clear opening at the primary entrance door; detached single-family houses are not covered (HUD).
- England: Approved Document M Volume 2 covers buildings other than dwellings. New dwellings meet M4(1); the M4(2) and M4(3) provisions apply only where a planning condition requires them, and both add a 300 mm nib at the leading edge. BS 8300-2:2018 is a code of practice that applies where the brief or contract calls it up.
- Australia: AS 1428.1 asks for 850 mm where it is called up; new houses and apartments follow the Livable Housing Design Standard’s 820 mm, as your state applies it.
Why is a heavy pivot leaf harder to make accessible?
Because of force and speed, not width. A self-closing pivot is the door closer: its spring, the seals and air pressure set the push needed, and the leaf’s weight adds inertia. Approved Document M Volume 2 says a self-closing non-powered door “is unlikely to be openable by many people”.
- Force, US: 404.2.9 limits interior hinged doors to 5 lbf (22.2 N). For exterior hinged doors, the Access Board’s guide says “a maximum opening force is not specified” and recommends automation where the force is likely to be significant. The limit covers continuous force, “not the initial force needed to overcome the inertia of the door”.
- Force, England: at the leading edge, not more than 30 N from 0° to 30° and 22.5 N from 30° to 60° (ADM Vol 2, 2.17(a)). BS 8300-2 gives the same figures, measured at the leading edge or in line with the handle up to 65 mm from it (GAI).
- Hand position: the force is measured near the edge, but people push at the pull. In our pull handle example, 30 N at the edge becomes about 65 N at mid-leaf, so keep the pull near the free edge.
- Closing speed: ADA 404.2.8.1 asks a closer to take at least 5 seconds from 90° to 12° from the latch. On a pivot door that is set in the hinge: FritsJurgens’ System M+ has Damper Control, a soft close at the end of the cycle, and 30° Speed Control, which slows the last 30°. Ask whether the setting reaches 5 seconds at your leaf weight, and have the installer time it.
- Hold-open: System M+ holds at 0°, 90° and −90°. A 90° hold keeps the full width while someone passes slowly, but ADM (2.8) also wants entrance doors “capable of being held closed when not in use”, and wind can beat a hold on an outward-opening leaf (pivot doors and wind).
- Power: ADM (2.10) calls a powered system “the most satisfactory solution for most people”, and 2.17(b) drops the 300 mm space beside the leading edge for a powered entrance door. Under the ADA, full-powered doors follow ANSI/BHMA A156.10, low-energy and power-assisted ones A156.19 (404.3). FritsJurgens says its System M+ FA NHO meets ICC A117.1-2017, which aligns with the ADA: at least 5 seconds from 90° to 12° and no more than 22.2 N to open. It is rated for pivot doors up to 300 kg, so a heavier leaf needs a powered operator or a different hinge. Plan the operator’s fixing, power and cable route before the leaf is made.
What threshold and floor space does an accessible pivot entrance need?
A near-level sill and clear floor on both faces. The ADA allows a 1/2 in (13 mm) threshold (404.2.5). Approved Document M Volume 2 wants it level or, if a raised threshold is unavoidable, 15 mm in total, with upstands over 5 mm “chamfered or rounded” (2.7(e)). The sill, floor plate and drop seal are in pivot door thresholds.
- Short side: it swings the other way, so any upstand changes face at the axis; a level sill avoids it.
- Landing: ADM Volume 2 asks for a level landing at least 1,500 × 1,500 mm, clear of any door swings, in front of the entrance (2.7(d)); M4(2) asks for 1,200 × 1,200 mm.
- Latch side, ADA: front approach, 1,525 mm deep and 455 mm beyond the latch on the pull side; 1,220 mm deep on the push side, plus 305 mm beyond the latch if there is a closer and a latch. Slopes no steeper than 1:48 (404.2.4.4).
- Latch side, England: 300 mm clear on the pull side beside the leading edge (2.17(b)). A wide leaf whose lock jamb sits tight in a corner fails both.
- Deep portals: if anything within 455 mm of the latch side projects more than 205 mm from the door face, the ADA needs forward-approach clearance (404.2.4.3).
Checklist: specifying an accessible pivot entrance
- Rule: which applies, confirmed with the authority, and how it measures width.
- Clear width at 90°, to the leaf face and to the pull.
- Opening: required width + axis distance + half the leaf + stop, plus the pull where counted.
- Opening direction: which face, and which pull, turns into the opening.
- Pull: projection, height and distance from the free edge.
- Leaf weight and pivot class, confirmed by the maker (size and weight).
- Force target, where it is measured, and who measures it at handover.
- Closing: self-closing or not, time from 90°, damping, hold positions.
- Power: operator, standard, fixing and cable route, or “none”.
- Threshold: height limit, sill, floor plate, drop seal, drainage.
- Floor space: landing, latch-side clearance on both faces, slopes, recess depth.
- Shop drawing: clear width dimensioned at 90°, pull included, checked by the architect (shop drawing checklist; full template in how to specify a pivot door).
How does this work with Dooream?
We make offset pivot doors up to 4,000 × 8,000 mm on pivot hinges, most often FritsJurgens, each made to the buyer’s drawing, from one door. We do not claim compliance with any accessibility standard. Ask us to dimension the axis, gaps, stop, pull and clear width at 90° on the shop drawing we send for approval; the architect checks the final clear width, threshold and closing settings on it against the rule that applies, before production. Production takes 35–45 days after drawing approval and the deposit, and your local installers fit and adjust the door with our installation drawings and remote guidance. See for architects.
Sources, checked November 2026: U.S. Access Board, 2010 ADA Standards, chapter 4 (404.2.3, 404.2.4, 404.2.5, 404.2.8, 404.2.9, 404.3) and guide to the ADA Standards, chapter 4: entrances, doors and gates; Cornell LII, 28 CFR 36.207, places of public accommodation in private residences; ADA National Network, does the ADA cover private apartments and private homes?; HUD, Fair Housing Act accessibility FAQ; GOV.UK, Approved Document M Volume 2, 2015 edition incorporating 2020 and 2024 amendments (2.7, 2.8, 2.9, 2.10, 2.13, 2.17, Table 2); Planning Portal, Approved Document M Volume 2; Ipswich Borough Council, Approved Document M Volume 1, 2015 edition (0.3, 1.14, 2.20, 3.22, Diagram 1.1); Guild of Architectural Ironmongers, Ironmongery and Accessibility specifier's guide, September 2024 (summarising BS 8300-2:2018); Sydney Access Consultants, AS 1428.1 door clear opening; ABCB, Livable Housing Design handbook 2022, version 1.1 (clause 2.1); FritsJurgens, System M+, System M+ FA NHO and M+ in depth: 30° Speed Control.
Quick answers
How much clear opening does an offset pivot door give?
Nearly the whole opening, less the axis distance, half the leaf thickness, the stop on the lock jamb and, under some rules, the pull that ends up in the opening. In our worked example, a 1,100 mm opening with an 80 mm leaf and a 70 mm pivot point gives 957 mm to the leaf face and 882 mm to a pull projecting 75 mm.
Can a pivot entrance door meet accessibility rules?
On width, yes, if the opening is sized for the rule: 815 mm under the 2010 ADA Standards, or 1,000 mm measured to the pull for external doors to new buildings used by the public under England's Approved Document M. The harder parts on a heavy leaf are opening force (30 N from 0° to 30° under Approved Document M), closing speed (at least 5 seconds from 90° to 12° under the ADA) and a threshold of 13 mm (ADA) or 15 mm (Approved Document M) at most.
Do accessibility rules apply to a private villa?
Usually not the rules for public buildings. The ADA does not cover strictly residential private homes, and the Fair Housing Act design rules exclude detached single-family houses. New homes in England must meet M4(1), a 775 mm clear opening, or 850 mm where a planning condition requires M4(2) or M4(3). In the US, any part of a home used as a place of public accommodation, including its entrance, is covered.