Guides

How heavy is an armoured entrance door, and what wall and fixings does it need?

How to estimate an armoured door leaf's weight from its layers, how the load reaches the wall or floor, and which walls, anchors and site checks a heavy entrance door needs.

By Alan, Dooream factory, Wuyi · 23 November 2026

A pale double door in a raw concrete opening, its frame wrapped in red protective film, with metal fixing lugs at intervals up both jambs, foam in the gap at the head and a green laser line near the floor
Installed: metal lugs hold the frame to the concrete up both jambs, and foam fills the gap at the head.

Short answer: add up the layers: each one’s thickness times its weight per millimetre (steel about 7.85 kg/m², aluminium 2.7, glass 2.5), plus edges and hardware. Our example sandwich comes to 52.8 kg/m², so a tall pivot leaf soon weighs several hundred kilograms. It needs solid structure at every fixing, a head that carries it, and anchors chosen from their maker’s data for that wall, confirmed by a local engineer.

How do you estimate the weight of an armoured door leaf?

Add up the layers. For each one, multiply its thickness in millimetres by its weight per square metre per millimetre, multiply the total by the leaf area, then add the edge profiles, lock, handles and hinge parts. Steel weighs about 7.85 kg/m² per mm, aluminium 2.7 and glass 2.5, from densities of about 7,850, 2,700 and 2,500 kg/m³.

The core adds little. Hexcel lists HexWeb CR III 5052 aluminium honeycomb at 1.0 to 12.0 lb/ft³, about 16 to 192 kg/m³; at 3.1 lb/ft³, about 50 kg/m³, a 50 mm core weighs 2.5 kg/m². Steel and faces decide the total (what is an armoured front door).

Our arithmetic, for an example build-up. It is not the weight of any of our doors:

Layer Thickness kg/m²
Outer face, aluminium sheet 4 mm 10.8
Galvanised steel sheet 2 mm 15.7
Aluminium honeycomb core, about 50 kg/m³ 50 mm 2.5
Galvanised steel sheet 2 mm 15.7
Inner face, aluminium sheet 3 mm 8.1
Total 52.8
Leaf W × H Area Layers Plus an assumed 10% for edges and hardware
1,100 × 2,400 mm, side-hinged 2.64 m² 139 kg About 153 kg
1,600 × 3,200 mm, pivot 5.12 m² 270 kg About 297 kg
Same pivot leaf, 20 mm aluminium plate face (96.0 kg/m²) 5.12 m² 492 kg About 541 kg

The face swings it: a 20 mm plate weighs 54 kg/m² before carving, less once carved. The last leaf is past the 500 kg top class in pivot door size and weight. The frame’s own weight is extra, and also goes into the fixings.

How does the load reach the wall or the floor?

On a side-hinged door the whole leaf hangs from the hinge jamb. Its weight acts about half the leaf’s width from the hinges, so the top hinge pulls out of the wall and the bottom one pushes in. On a pivot door the floor carries the leaf and the head holds it upright.

  • Side-hinged: fixings behind the hinge jamb take shear from the weight and tension at the top hinge, so the anchor data must cover both (hinges for heavy doors works out the forces).
  • Pivot: the bottom pivot stands on the finished floor and the top pivot pushes sideways on the head, so the head needs structure, not a ceiling (floor preparation, offset and centre pivots).
  • Both: the lock jamb takes the bolts, slamming and any levering, so it needs fixings into structure as much as the hinge side.

Which walls can carry it, and what should be checked?

Reinforced concrete and solid masonry take fixings direct. Hollow block, perforated brick, aerated concrete, timber and steel stud walls usually need special anchors, filled cores or a steel subframe; a door set in external insulation needs a structural subframe through to the wall. The anchor maker’s data for that exact wall decides.

Wall Typical fixing What to check
Reinforced concrete Frame screws, frame anchors, or steel lugs on anchors Rebar and services where you drill; edge distance
Solid brick, solid block, stone Frame screws, frame anchors or injection anchors Unit and mortar strength; unit or joint at each fixing
Hollow block, perforated brick Injection anchors in mesh sleeves; filled cores; steel posts Block type named in the anchor’s data; site tests
Aerated concrete Anchors made for aerated concrete; concrete or steel posts Edge distance; site tests
Timber frame Structural screws into studs and header; steel subframe Studs and header sized for the leaf weight; packers at every fixing
Steel frame Bolted or welded to steel posts or a subframe Post sizes; coatings repaired after welding
External insulation (ETICS) or cladding Brackets or a projecting subframe anchored into the wall behind Subframe rating against leaf plus frame; no fixing into the insulation
  • Frame screws and frame anchors go through the frame into the wall. fischer’s FFS frame screw needs no plug and is listed for concrete, solid and perforated brick and aerated concrete; its F-S frame anchor is a nylon plug with a screw.
  • Injection anchors suit hollow and perforated units: mortar is pressed through a mesh sleeve into the holes, and, in fischer’s words, “the load is borne by the interlock”.
  • Edge distance matters on an armoured door. In burglary tests reported by Küenzlen and Scheller (Mauerwerk-Kalender 2022), a 30 mm edge distance allowed significant damage to a concrete edge, and 60 mm in aerated concrete proved far too small. For hollow clay brick they require the frame in the middle third of the wall, to keep fixings far from the edge.
  • External insulation cannot carry a door. G-U says that when windows and balcony doors move into the insulation layer, it “cannot carry and transfer the loads”; its brackets give them stability up to 250 kg, and its projecting frame is tested to 579 kg. The example pivot leaf above already exceeds the first figure.
A black single door with a white band and a smart lock in a wall finished with grooved beige panels, with red brick and a row of metal pins showing in the unfinished gap above the frame and rough mortar at both jambs
Installed, before the reveals were finished: brick shows in the gap above the frame, behind the wall's finish.

What must the engineer or installer confirm?

Three things: that the head carries the wall above and any top pivot; that every anchor suits its wall, at the edge distance and spacing its maker requires; and that the anchors’ published loads cover the real door weight. Where data does not cover the wall, test on site before hanging the door.

  • Lintel and head. The frame must not carry the wall above; for a new or enlarged opening, see the lintel notes in replacing a villa front door.
  • Edge distance and spacing, from the anchor maker’s data, measured to the reveal, both wall faces and any joint.
  • Load data for that wall, in tension and shear. fischer’s frame anchor loads are for a single anchor in multiple fixings of non-structural systems; the engineer sets how many the door needs.
  • Site tests where data does not cover the wall: fischer says allowable resistance tests are “particularly common in masonry”, and proof tests check a sample of installed anchors. In the UK, BS 8539:2012+A1:2021 is the code of practice for selecting and installing post-installed anchors in concrete and masonry.
  • Fixing spacings and frame tolerances: as the installation drawing says; general figures are in the installer’s checklist.
  • Burglar-resistant doors. For a door tested to EN 1627, the wall is part of the rating: the German edition, DIN EN 1627:2011-09, as reproduced by Küenzlen and Scheller, asks for masonry at least 115 mm thick without plaster up to RC 3 and 240 mm from RC 4, and reinforced concrete from 100 mm for RC 2 to 140 mm from RC 4. We hold no EN 1627 rating.

How deep is the frame, and how thick must the wall be?

The frame depth and wall thickness must agree on the drawing. Our frames are 125 mm deep as standard, in steel or aluminium with a 2 mm wall, and the depth can be made to suit the wall. Decide early where in the wall’s depth the frame sits: that decides what its fixings go into.

  • Thinner wall: a shallower frame, or one that stands proud with a lining.
  • Thicker wall: the frame at one face or in the middle, with linings over the rest; fixings and edge distances follow that position.
  • Insulated wall: the frame in the masonry plane with the insulation returned into the reveal, or in the insulation plane on a subframe.

What should be ready on site before the door arrives?

The structure, not just the hole. By delivery the engineer should have the real weights, every fixing point should be known to be in solid material, and any lintel, posts or subframe should be built and approved; otherwise the leaf waits on site.

  1. Leaf and frame weights from the approved shop drawing, with the engineer.
  2. Wall material confirmed at every fixing point by drilling or opening up.
  3. Lintel or head beam in place and approved; for a pivot, structure at the top pivot.
  4. Filled cores, steel posts or subframe built where the engineer asked.
  5. Anchors chosen for that wall, maker’s data on file, site tests done where needed.
  6. Frame position in the wall’s depth agreed, and edge distances checked against it.
  7. Wall thickness, finishes included, at both jambs and the head, matching the frame depth on the drawing (what to send).
  8. On an insulated or clad wall, the subframe in and its rating checked against the weight.
  9. Floor ready: sill bearing for a hinged door, finished floor for a pivot plate.
  10. Pipes, cables and slab tendons located; ask the engineer before anyone drills a post-tensioned slab.

How does this work with Dooream?

Every order comes with installation drawings, and the shop drawing gives the real leaf weight for your engineer to work from. Our leaves have a 2 mm galvanised steel sheet each side of an aluminium profile frame with an aluminium honeycomb core, behind front and inner panels; frames are 125 mm deep as standard, or made to suit the wall. Your local installers fit the door with our remote guidance; your local engineer checks the wall and opening. Send the opening, wall build-up and photos via our contact page.

Sources, checked November 2026: Eurocode Applied, steel design properties; ArcelorMittal, Orange Book, dimensions of sections (steel density 7,850 kg/m³); Royal Society of Chemistry, aluminium; Guardian Glass, physical properties of glass; Hexcel, HexWeb CR III data sheet; J. Küenzlen and E. Scheller, Montage von Fenstern und Türen mit Anforderungen an die Einbruchhemmung, Mauerwerk-Kalender 2022 (Ernst & Sohn), special print; G-U, projecting installation brochure; fischer, window frame screws FFS, window frame fixing F-S, injection anchor sleeve FIS H K and site testing; BSI, BS 8539:2012+A1:2021.

Quick answers

How heavy is an armoured entrance door?

It depends on the layers. Multiply each layer's thickness by its weight per millimetre (steel about 7.85 kg/m², aluminium 2.7, glass 2.5) and add edges and hardware. Our example sandwich of aluminium faces, two 2 mm steel sheets and a honeycomb core comes to 52.8 kg/m², so a 1,100 × 2,400 mm leaf is about 153 kg with an assumed 10% for edges and hardware. That is arithmetic, not the weight of our doors; the real leaf weight is on the shop drawing.

What kind of wall does a heavy armoured door need?

Solid structure at every fixing. Reinforced concrete and solid masonry take fixings direct; hollow block, aerated concrete, timber and steel stud walls usually need special anchors, filled cores or a steel subframe; a door set in external insulation needs a structural subframe through to the wall. The head needs a lintel or beam. A local engineer confirms it.

Which anchors are used to fix a heavy door frame?

Frame screws, frame anchors or steel lugs on anchors in concrete and solid masonry, and injection anchors in mesh sleeves in hollow or perforated block. Choose them from the anchor maker's data for that exact wall, with its edge distances. Where the data does not cover the wall, test on site: fischer says such tests are particularly common in masonry.

Ask the factory

Send us your opening.

A photo or a rough size is enough to start. The first design direction is free, usually within one working day. We reply on WhatsApp within 12 hours.

WhatsApp +86 156 5891 0546What to send us