Double or triple glazing in an entrance door: insulated glass, low-E coatings and gas fill

How insulated glass units work in and beside entrance doors, double vs triple, low-E surfaces, argon and krypton, Ug vs door U-value, g-value, weight, fogging, altitude and EN 1279.

By Alan, Dooream factory, Wuyi · 16 November 2026

A tall dark double door below a deep dark panel and a large clear glazed transom in a dark frame, with two thin full-height lines of light near the centre and boxes on the unfinished floor, installed
A large glazed transom over a double door, installed, the kind of fixed pane whose gas, coatings and weight are settled on the drawing.

Short answer: an insulated glass unit (IGU) is two or three panes sealed round a spacer, with dry air or argon between them. In a cool climate, a double unit with low-E and argon, about Ug 1.0 W/m²K, is the usual baseline; triple glazing, down to 0.5, pays where cold or rules demand it and the leaf can carry the weight. In hot climates the g-value matters more than Ug.

What is an insulated glass unit?

An insulated glass unit (IGU, or sealed unit) is two or more panes held apart by a spacer bar and sealed round the edge. The spacer holds desiccant to keep the gap dry; the gap holds dry air or a heavier gas, and one pane usually carries a low-emissivity (low-E) coating.

Surfaces are numbered from outside: 1 faces the weather, 2 and 3 face the cavity, 4 the room; a triple unit runs to 6. A build-up of 4-16-4 means 4 mm glass, a 16 mm cavity, 4 mm glass. A door’s safety panes sit within the unit, typically toughened outside, laminated inside; see glass in entrance doors.

Double or triple glazing: what is the difference?

With a third pane and two low-E coatings, triple glazing halves the centre-of-glass U-value (Ug) of a good double unit, from about 1.0 to 0.5 W/m²K, but weighs half as much again and lets in less light. A thin triple unit with one coating gains almost nothing.

Build-up, outside to inside Ug (W/m²K) LT and g Glass weight* Thickness
Double 4-20-4, air, one low-E 1.5 g 0.70 20 kg/m² 28 mm
Double 4-20-4, argon, one low-E 1.2 g 0.71 20 kg/m² 28 mm
Double 4-16-4, 90% argon, low-E on surface 3 1.0 LT 77%, g 0.57 20 kg/m² 24 mm
Double 6-16-4, 90% argon, solar control on surface 2 1.0 LT 60%, g 0.27 25 kg/m² 26 mm
Triple 4-8-4-8-4, argon, one low-E 1.3 – 30 kg/m² 28 mm
Triple 4-12-4-12-4, argon, two low-E 0.8 – 30 kg/m² 36 mm
Triple 4-16-4-16-4, 90% argon, low-E on 2 and 5 0.5 LT 66%, g 0.43 30 kg/m² 44 mm

*Our arithmetic, glass only, at 2.5 kg/m² per mm. Centre-of-glass values: rows 1, 2, 5 and 6 from the Glass and Glazing Federation (2016); rows 3, 4 and 7 from AGC (2024), Ug to EN 673, LT and g to EN 410. Door panes are usually thicker.

Which surface should the low-E coating be on?

For night-time heat loss a low-E coating works the same on surface 2 or 3, says Pilkington; the difference is the sun. A solar-control coating must sit on surface 2, because on surface 3, behind clear glass, it would trap the sun’s heat and drive it inwards.

  • Cold and temperate climates: a thermal low-E coating. AGC’s thermal double units put it on surface 3, with g 0.57, so winter sun still helps (cold climates).
  • Hot climates: solar-control low-E on surface 2.
  • Triple units: coatings on surfaces 2 and 5 (AGC), or 2 and 4 or 5 (Glass Canada).

Argon or krypton, and how wide a cavity?

Argon is the standard fill, worth 0.3 W/m²K in the GGF’s 4-20-4 example. Krypton pays only in slim units; Saint-Gobain says that in a 16 mm cavity it brings a negligible benefit over argon.

Wider is not always better, as the gas starts to circulate: in Saint-Gobain’s example a unit at 1.0 W/m²K with 16 mm of argon may reach only 1.1 at 20 mm; its optimum triple cavities are 18.5 mm for argon and 12.2 mm for krypton.

Gas leaks out slowly. EN 1279-3:2018 allows 1.0% a year on average, and a unit declared at 90% argon must still hold at least 85% after testing.

Does a good Ug make a good door?

No. Ug is the centre of the glass only, to EN 673. The whole-door value, Ud, adds the frame, leaf, threshold and glass edge, so triple glass in an unbroken aluminium frame still makes a cold door; see door U-value explained and thermal breaks.

At the edge, an aluminium spacer carries heat round the cavity. A warm-edge spacer improves a window’s U-value by about 0.1 W/m²K in timber or PVC frames and up to 0.2 in metal ones, says warm-edge adviser Ingrid Meyer-Quel, and keeps the edge warmer against condensation.

What matters in a hot climate?

In the Gulf or an Australian summer, keeping the sun out matters more than Ug. Specify the solar factor, g, and light transmission, LT (EN 410). In AGC’s tables a solar-control double unit gives g 0.27 with LT 60%; a triple thermal unit, despite Ug 0.5, still lets through g 0.43.

Our arithmetic: at 45 °C outside and 24 °C in the hall, halving Ug from 1.0 to 0.5 saves about 10 W per m² of glass; cutting g from 0.43 to 0.27 saves 16 W of every 100 W of sun on the pane. Shade first (hot climates). In Dubai, Al Sa’fat clause 501.01 sets envelope requirements for the thermal transmittance, shading coefficient and light transmittance of glass, with certified products.

How much weight does insulated glass add to a door?

Glass weighs 2.5 kg/m² per millimetre of thickness, says Guardian Glass, and door panes are thicker than 4 mm because they must be safety glass. Our arithmetic, glass only:

  • Double, 6 mm toughened and a laminate of two 4 mm panes: 14 mm of glass, 35 kg/m².
  • Triple, the same plus a 4 mm centre pane: 18 mm, 45 kg/m².
  • A 1,000 × 2,400 mm pane: about 84 kg double, 108 kg triple.

Add that to the leaf and check the pivot or hinge rating (size and weight, hinges, pivot doors with glass). The GGF warns that triple glazing may shorten hinge life and needs setting blocks as deep as the unit. Eckelt asks for setting blocks 80–100 mm long and at least 5 mm thick. Where you can, put big panes in fixed sidelights, not the leaf.

A dark pivot door with a long vertical pull, standing open between two full-height clear glass sidelights in a dark frame, under a canopy, with trees seen in the glass, installed
Installed: full-height glass in fixed sidelights, so the pivot leaf does not carry its weight.

Why does glass fog between the panes?

The edge seal has let in more moisture than the desiccant can hold. IGU seals are not hermetic: vapour creeps in and argon leaks out, writes Helen Sanders of Technoform (USGlass, 2024). Once the desiccant is full, water condenses inside, out of reach, and the unit must be replaced. Eckelt’s guidelines name what shortens seal life:

  • Sun on the edge seal. Cover it with frame or bead, or use UV-resistant sealant where the edge shows, as on a frameless pane; silicone resists heat, UV and water, Sanders notes.
  • Standing water. Drain and vent the rebate at its lowest point; keep setting blocks from damming water.
  • Incompatible materials. Gaskets, sealants and blocks must suit the edge seal.
  • Storage. Upright and dry; stacked units left in the sun can crack.

Can insulated glass travel by air or over mountains?

A unit is sealed at the factory’s air pressure; where pressure is lower, the gas expands, the panes bow and the seal is strained. Eckelt asks to be told at order if the site is over 800 m above sea level, and Construction Canada notes that even a brief crossing of a 3,048 m pass can matter. In the air, US rules let an airliner’s occupied cabin reach a pressure altitude of 8,000 ft (about 2,440 m); ask the forwarder about the hold.

Capillary tubes through the spacer let the pressure even out, but only in air-filled units: Vitro says the gas would leak out of gas-filled ones, and that tubes should be crimped and sealed once the unit has settled at its destination. Cardinal does not sell argon-filled units for high altitude. Sea freight stays at sea level, so for argon units check the inland route.

Which standards and marks should you ask for?

Ask for long-term test evidence for the edge-seal system, and check your units use the spacer, sealants and gas tested.

Market Standard or mark What it covers
Europe EN 1279-2:2018 Moisture penetration, long-term test
Europe EN 1279-3:2018 Gas leakage rate and gas concentration
US, Canada IGCC/IGMA certification to ASTM E2190 IGU performance; NAFS windows need it or CAN/CGSB-12.8
Australia, New Zealand AS/NZS 4666:2012 Type and production tests; not thermal, solar or light values

Australian Glass Group, a processor, says AS 4666 is mandatory under the NCC deemed-to-satisfy path; confirm with your certifier.

What should the glazing specification say?

  1. Each pane: position, visible size, fixed or in the leaf.
  2. Build-up, outside to inside: each pane’s thickness, type and safety class (acoustic glass).
  3. Gas and cavities: argon or krypton, declared fill, widths.
  4. Coatings: thermal or solar control, and surface numbers.
  5. Spacer: warm edge, named, with its colour.
  6. Values: Ug to EN 673, g and LT to EN 410, and Ud for the whole door.
  7. Weight: per unit and per leaf, against the pivot or hinge rating.
  8. Edge-seal evidence: EN 1279-2 and -3, IGCC or AS/NZS 4666.
  9. Edge and rebate: seal covered or UV-resistant; drained rebate; setting blocks.
  10. Route: site altitude, highest point in transit, any air leg.

How does this work with Dooream?

Glass is one of the face materials we make. We sell complete doors only, made to the buyer’s drawings, so write each pane’s build-up on the drawing. Our thermal-break construction, with PA66 polyamide insulating strips in the aluminium profiles, reaches a U-value of 1.0 W/m²K in our test report, and any of our designs can be built with it; a glazed door’s own value still depends on its glass, size and threshold. If your project needs a Ug, g-value or edge-seal document, agree it with us before production; a lab test can be arranged, usually at the buyer’s cost. See our page for architects or send us the opening.

Sources, checked November 2026: Glass and Glazing Federation, triple glazing guidance (2016); AGC, Pocket Value (March 2024); Saint-Gobain Building Glass UK, thermal insulation technical guidance; Pilkington, technical bulletin ATS-164 (2013); Glass Canada, the engineer: low-E lowdown (2018); EVS, EN 1279-2:2018 and EN 1279-3:2018; Sparklike on glassonweb, gas concentration and EN 1279-3:2018 (2025); Ingrid Meyer-Quel, warm edge and psi values; Dubai Municipality, green building regulations and Al Sa'fat; Guardian Glass, physical properties of glass; Eckelt, general glazing guidelines for insulating glass (2024); Helen Sanders on Technoform, insulating glass seals are not hermetic (2024); Construction Canada, compensating for internal pressure changes (2022); Vitro, TD-103, capillary tubes in insulating glass units (2023); Cardinal IG, IG13, capillary and breather tubes (2020); Cornell Legal Information Institute, 14 CFR 25.841, pressurized cabins; FGIA, insulating glass certification; Standards New Zealand on Building CodeHub, AS/NZS 4666:2012; Australian Glass Group on Archify, AS 4666 mandatory compliance.

Quick answers

Is triple glazing worth it in a front door?

Where the cold or the energy rules demand it and the leaf can carry it. In AGC's tables a triple unit with two low-E coatings and argon reaches Ug 0.5 W/m²K against 1.0 for a good double unit, but each extra 4 mm pane adds 10 kg/m² and light transmission falls from 77% to 66%. A thin triple unit with one coating gains almost nothing, and in hot climates the g-value matters more than Ug.

Which surface should the low-E coating be on?

Surfaces are numbered from outside. A solar-control coating must be on surface 2 to keep the sun's heat out. A thermal low-E coating works the same on surface 2 or 3 for night-time heat loss, says Pilkington, and AGC's thermal double units put it on 3. Triple units carry two coatings, on surfaces 2 and 5 in AGC's tables.

Why is there condensation between the panes of my door glass?

The edge seal has let in more moisture than the desiccant in the spacer can hold. It cannot be wiped off; the unit has to be replaced. Sun on an unprotected edge seal, water standing in the glazing rebate and incompatible sealants or gaskets all shorten seal life.

Ask the factory